Schneider

TWDLCDA40DRF | Schneider 24 V DC Compact PLC Controller

  • Model TWDLCDA40DRF
  • Condition In Stock
4.6/5 (16 reviews)
$262.00 Indicative price · request a quote for availability

Upgrade your automation with the Schneider TWDLCDA40DRF compact PLC base controller. 24 V DC supply, 24 inputs, 16 outputs, Modbus serial link. In stock at SpareTechPLC.

Product Description

TWDLCDA40DRF Overview

When your control system demands a compact yet powerful controller, the Schneider TWDLCDA40DRF delivers. This compact base controller from the Twido series integrates 24 digital inputs and 16 outputs in a single, space-saving unit. It operates on a 24 V DC supply, making it a perfect fit for modern industrial panels. The TWDLCDA40DRF is commercialised and ready to support your automation needs.

Figure 1: Front view of the Schneider TWDLCDA40DRF industrial automation component showing its physical design and enclosure.

Key Technical Specifications

Understanding the exact capabilities of the TWDLCDA40DRF ensures you select the right controller for your application. Here are the critical specifications:

| Specification | Value |

|—|—|

| Supply Voltage | 24 V DC |

| Input Voltage | 24 V DC |

| Discrete Inputs | 24 |

| Discrete Outputs | 2 transistor, 14 relay |

| Program Memory | 3000 instructions |

| Real-time Clock | Yes, drift ≤ 30 s/month |

| Communication | Modbus/character mode master/slave RTU/ASCII (RS485) |

| Operating Temperature | 0…55 °C |

| Protection | Internal fuse, IP20 |

This controller supports up to 7 I/O expansion modules, allowing you to scale your system as needed. With a maximum I/O count of 264 (using HE-10 connectors), the TWDLCDA40DRF grows with your application.

Solving Your Control Challenges

Flexible Input Configuration

The TWDLCDA40DRF accepts both sink and source input logic, simplifying integration with various sensors and switches. Input voltage limits range from 20.4 to 26.4 V DC, ensuring stable operation even with fluctuating power supplies. The discrete input current varies from 7 mA to 11 mA depending on the input group, providing reliable signal detection.

Reliable Output Switching

With 2 transistor outputs for high-speed switching and 14 relay outputs for versatile load control, this controller handles mixed loads effortlessly. Relay outputs can switch 2 A at 30 V DC or 240 V AC, both resistive and inductive loads, with a mechanical durability of over 20 million cycles. This ensures long-lasting performance in demanding environments.

Built-in Communication

The integrated non-isolated serial link (RS485) supports Modbus RTU/ASCII master/slave protocols, enabling seamless connectivity to HMIs, drives, and other PLCs. The half-duplex communication at 38.4 kbit/s provides reliable data exchange for most industrial applications.

Figure 2: Technical layout and connection details for the Schneider TWDLCDA40DRF industrial automation component.

Real-World Applications

The TWDLCDA40DRF excels in various automation scenarios:

  • Packaging Machinery: Control conveyor systems, counting inputs, and actuator outputs with precision. The high-speed counter inputs (up to 20 kHz on 2 channels) handle fast production lines.
  • HVAC Systems: Manage fans, pumps, and dampers using the relay outputs. The built-in PID control simplifies temperature and pressure regulation.
  • Material Handling: Coordinate sorting and routing operations. The compact size allows mounting in tight control panels.

Installation and Setup

Mounting the TWDLCDA40DRF is straightforward. You can install it on a 35 mm symmetrical DIN rail or a plate/panel using the optional fixing kit. The non-removable screw terminal block ensures secure wiring connections. Remember to maintain proper clearance for ventilation and follow the recommended operating temperature range of 0 to 55 °C.

Maintenance and Reliability

Designed for long service life, the TWDLCDA40DRF includes an internal RAM backup with a lithium battery that lasts up to 10 years. The real-time clock maintains accurate time for up to 30 days without power. Regularly inspect the unit for dust accumulation and ensure the ambient temperature stays within limits. With proper care, this controller provides years of trouble-free operation.

Compatibility and Integration

The TWDLCDA40DRF is part of the Schneider Twido family, ensuring compatibility with a wide range of expansion modules and accessories. Use the serial link to connect to Schneider drives, HMIs, or third-party devices supporting Modbus. The controller also supports memory cartridges for program backup and transfer.

Why Choose SpareTechPLC?

SpareTechPLC offers genuine Schneider parts with expert support. We understand that downtime costs money, so we stock the TWDLCDA40DRF for immediate shipment. Our team can help you verify compatibility and provide technical guidance. Contact us today to order or ask questions.

Frequently Asked Questions

What is the supply voltage for the TWDLCDA40DRF?

The TWDLCDA40DRF requires a 24 V DC supply, with an allowable range of 20.4 to 28.8 V DC.

How many inputs and outputs does this controller have?

It has 24 discrete inputs (24 V DC) and 16 discrete outputs: 2 transistor and 14 relay.

Can I expand the I/O count?

Yes, you can connect up to 7 I/O expansion modules, achieving a maximum of 264 I/O points with HE-10 connectors.

What communication protocols are supported?

The integrated serial link supports Modbus RTU/ASCII master/slave protocols via RS485.

Does the TWDLCDA40DRF have a real-time clock?

Yes, it includes a real-time clock with a drift of ≤30 seconds per month and a backup time of 30 days.

Specifications

Model / No. TWDLCDA40DRF
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $262.00

Additional Information

TWDLCDA40DRF
compact PLC base Twido - 24 V DC supply -
24 I 24 V DC - 16 O

Main
Commercial Status Commercialised
Range of product Twido
Product or component
type
Compact base controller
Discrete I/O number 40
Discrete input number 24
Discrete input voltage 24 V
Discrete input voltage
type
DC
Discrete output number 2 for transistor
14 for relay
[Us] rated supply voltage
24 V DC
Number of I/O expansion module
7
Use of slot Memory cartridge
Data backed up Internal RAM (lithium) 30 days, charging time = 10
h, battery life = 10 yr
Integrated connection
type
Non isolated serial link mini DIN, Modbus/character
mode master/slave RTU/ASCII (RS485) half duplex,
38,4 kbit/s
Serial link interface adaptor (RS232C/RS485)
Power supply
Complementary function
Event processing
PID

Complementary
Discrete input logic Sink or source
Input voltage limits 20.4...26.4 V
Discrete input current 7 mA for I0.8 to I0.23
7 mA for I0.2 to I0.5
11 mA for I0.6 to I0.7
11 mA for I0.0 to I0.1
Input impedance 3400 Ohm for I0.8 to I0.23
3400 Ohm for I0.2 to I0.5
2100 Ohm for I0.6 to I0.7
2100 Ohm for I0.0 to I0.1
Filter time 40 µs + programmed filter time for I0.6 to I0.23 at state 1
40 µs + programmed filter time for I0.0 to I0.5 at state 0
35 µs + programmed filter time for I0.0 to I0.5 at state 1
150 µs + programmed filter time for I0.6 to I0.23 at state 0
Insulation between channel and internal logic 1500 Vrms for 1 minute
Insulation resistance between channel None
Minimum load 0.1 mA
Contact resistance = 20000000 cycles for relay output
Electrical durability >= 100000 cycles for relay output

Current consumption 90 mA at 5 V DC at state 1
70 mA at 5 V DC at state 0
5 mA at 24 V DC at state 0
140 mA at 5 V DC state 1 + input ON
128 mA at 24 V DC state 1 + input ON
128 mA at 24 V DC at state 1
I/O connection Non-removable screw terminal block
Input/Output number <= 264 with HE-10 connector with I/O expansion module <= 208 with spring terminal block with I/O expansion module <= 152 with removable screw terminal block with I/O expansion module Supply voltage limits 20.4...28.8 V Inrush current <= 35 A Protection type Power protection with internal fuse Power consumption 10 MOhm at 500 V, between supply and earth terminals
> 10 MOhm at 500 V, between I/O and earth terminals
Program memory 3000 instructions
Exact time for 1 K instruction 1 ms
System overhead 0.5 ms
Memory description Internal RAM, floating, trigonometrical
Internal RAM, double words, no floating, no trigonometrical
Internal RAM, 3000 internal words, no floating, no trigonometrical
Internal RAM, 256 internal bits, no floating, no trigonometrical
Internal RAM, 128 timers, no floating, no trigonometrical
Internal RAM, 128 counters, no floating, no trigonometrical
Free slots 1
Realtime clock With, drift: <= 30 s/month, operating time: 30 days Positioning functions PWM/PLS 2 channel(s) at 7 kHz Counting input number 4 channel(s) at 5000 Hz 16 bits 2 channel(s) at 20000 Hz 32 bits Analogue adjustment points 1 point adjustable from 0...1023 1 point adjustable from 0 to 511 points Status LED 1 LED red for module error (ERR) 1 LED per channel green for I/O status 1 LED green for RUN 1 LED green for PWR 1 LED for user pilot light (STAT) Product weight 0.525 kg Environment Immunity to microbreaks 10 ms Dielectric strength 500 V for 1 minute, between supply and earth terminals 1500 V for 1 minute, between I/O and earth terminals Product certifications CSA UL Marking CE Ambient air temperature for operation 0...55 °C Ambient air temperature for storage -25...70 °C Relative humidity 30...95 % without condensation IP degree of protection IP20 Operating altitude 0...2000 m Storage altitude 0...3000 m Vibration resistance 4 gn, 25...100 Hz mounting on: plate or panel with fixing kit 1.6 mm, 2...25 Hz mounting on: plate or panel with fixing kit 1 gn, 57...150 Hz mounting on: 35 mm symmetrical DIN rail 0.075 mm, 10...57 Hz mounting on: 35 mm symmetrical DIN rail Shock resistance 15 gn for 11 ms Not classified Depth 70 mm Height 95 mm Width 90 mm

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Schneider_TWDLCDA40DRF_Service_Manual.pdf)