Why settle for imprecise temperature readings?
In industrial processes, a few degrees of error can mean the difference between product quality and costly waste. The TSXAEY1614 from Schneider Electric addresses this challenge head-on, delivering high-resolution analog input capabilities that ensure your temperature and voltage measurements are accurate and reliable.

What Is the TSXAEY1614?
The TSXAEY1614 is an analog input module designed for Schneider Electric’s TSX Micro PLC series. It provides 16 high-level input channels, each capable of 16-bit analog-to-digital conversion. This module supports a wide range of thermocouple types—B, E, J, K, L, N, R, S, T, and U—as well as voltage inputs of +/- 80 mV. This versatility makes it a valuable asset in diverse automation systems.
Key Technical Specifications
| Specification | Value |
|—|—|
| Analog Input Channels | 16 high-level inputs |
| Analog/Digital Conversion | 16 bits |
| Input Types | Thermocouple (B, E, J, K, L, N, R, S, T, U), Voltage (+/- 80 mV) |
| Nominal Read Cycle Time | 70 ms per channel |
| Isolation | 1000 Vrms between channels and bus, 1000 Vrms between channels and ground |
| Common Mode Voltage | 250 V AC or 280 V AC between channels, 250 V DC between channels and earth |
| Electrical Connection | 2 connectors SUB-D 25 |
| Input Overvoltage Protection | -15 to 15 V at state 0, -30 to 30 V at state 1 |
| Current Consumption | 300 mA at 5 V DC |
| Operating Temperature | 0 to 60°C |
| Storage Temperature | -25 to 70°C |
| Relative Humidity | 10 to 95% without condensation for operation |
| Standards | NFC 42-330, IEC 1131, DIN 43710, IEC 751, DIN 43760, IEC 584 |
| Product Certifications | DNV, RMRS, LR, ABS, RINA, BV, GL |
| IP Degree of Protection | IP20 |

Real-World Applications
The TSXAEY1614 excels in applications requiring precise temperature monitoring and control. Consider these scenarios:
- Process Control: In chemical or pharmaceutical plants, accurate temperature readings are critical. The module’s support for multiple thermocouple types allows you to standardize on one input module for various sensors, simplifying spare parts management.
- HVAC Systems: For large commercial buildings, the TSXAEY1614 can monitor temperatures across multiple zones, ensuring comfort and energy efficiency.
- Test & Measurement: In laboratory or test setups, the high 16-bit resolution and low measurement error (e.g., 0.8°C for thermocouple E at 25°C) provide confidence in data accuracy.
Installation & Setup Guidance
Installing the TSXAEY1614 is straightforward. The module fits into a standard TSX Micro PLC rack. Use the two SUB-D 25 connectors for wiring. Ensure that thermocouple wires are properly shielded and routed away from power cables to minimize noise. The module provides input overvoltage protection (-15 to 15 V at state 0, -30 to 30 V at state 1), but you should still verify that your sensors and wiring meet the module’s specifications before connection.
Maintenance & Reliability
Routine maintenance is minimal. Periodically check that all connectors are secure and that the module’s ventilation is not obstructed. The module operates in temperatures from 0 to 60°C and can be stored between -25 and 70°C. Keep the environment free of condensation, as the relative humidity limit is 10 to 95% without condensation. Following these simple practices will help ensure long-term reliability.
Compatibility & Integration
The TSXAEY1614 is part of the TSX Micro PLC family, so it integrates seamlessly with other TSX Micro modules. It complies with several international standards, including IEC 1131, which ensures interoperability in many industrial settings. The module also carries certifications from major classification societies like DNV, LR, ABS, and others, making it suitable for marine and offshore applications.
Selection Guide & Purchasing Advice
Before purchasing, confirm that your PLC base is compatible with the TSXAEY1614. Also, verify the required thermocouple types and voltage ranges match your application. At SpareTechPLC, we stock the TSXAEY1614 and can help you confirm compatibility. Contact us for current availability and lead times.
Troubleshooting & Common Issues
If readings seem inaccurate, first check the thermocouple type selection and wiring. Ensure that the cold junction compensation is properly configured. If the module does not communicate, verify that it is firmly seated in the rack and that the bus connector is clean. For persistent issues, consult the module’s documentation or contact SpareTechPLC for technical support.
Frequently Asked Questions
What thermocouple types does the TSXAEY1614 support?
The TSXAEY1614 supports thermocouple types B, E, J, K, L, N, R, S, T, and U, as well as voltage inputs of +/- 80 mV.
What is the measurement error for thermocouple E?
At 25°C, the measurement error for thermocouple E is 0.8°C. For the full operating range of 0 to 60°C, the error is 1.2°C.
Can the TSXAEY1614 be used in marine environments?
Yes, it holds certifications from DNV, RMRS, LR, ABS, RINA, BV, and GL, making it suitable for marine and offshore applications.
What is the isolation rating of the TSXAEY1614?
The module provides 1000 Vrms isolation between channels and the bus, and also between channels and ground.
What is the power consumption of the TSXAEY1614?
The module consumes 300 mA at 5 V DC.