TSXAEY1600 Overview
When your TSX Micro PLC needs precise analog signal acquisition, the Schneider Electric TSXAEY1600 delivers a dependable, high-density solution. This standard-format module provides 16 high-level analog input channels with 12-bit analog-to-digital conversion. It supports a versatile mix of current and voltage inputs, making it a flexible choice for diverse industrial processes. By upgrading to the TSXAEY1600, you gain a robust interface that streamlines wiring and simplifies maintenance.

Key Technical Specifications
The TSXAEY1600 is engineered for accuracy and speed. Below are the critical specifications you need to evaluate:
| Parameter | Value |
| — | — |
| Analog Input Channels | 16 high-level |
| Input Types | Current: 0–20 mA, 4–20 mA; Voltage: ±10 V, 0–10 V, 0–5 V, 1–5 V |
| Analog/Digital Conversion | 12 bits |
| Nominal Read Cycle Time | 51 ms |
| Fast Read Cycle Time | 3 ms + 3 ms per channel used |
| Measurement Error | 0.1% of full scale at 25°C (voltage ranges) |
| Isolation | 1000 Vrms between channels and bus; 1000 Vrms between channels and ground |
| Current Consumption | 270 mA at 5 V DC |
| Electrical Connection | 2 connectors SUB-D 25 |
| Operating Temperature | 0 to 60°C |
| Storage Temperature | -25 to 70°C |
| Relative Humidity (Operation) | 10 to 95% without condensation |
| IP Degree of Protection | IP20 |
Each channel accepts either current or voltage signals, giving you the flexibility to interface with a wide range of sensors and transmitters. The fast read cycle time of 3 ms plus 3 ms per active channel allows for rapid data acquisition in time-critical applications.
Real-World Applications
The TSXAEY1600 excels in applications that demand simultaneous monitoring of multiple analog signals. Use it in:
- Process Control: Monitor temperature, pressure, and flow transmitters with 4–20 mA outputs. The module’s 0.1% accuracy ensures reliable process data.
- Machine Monitoring: Connect voltage outputs from vibration sensors or position transducers (±10 V) to track equipment health in real time.
- Batch Processing: Read multiple analog inputs from scales or flow meters to precisely control ingredient addition.

Installation and Setup
Integrating the TSXAEY1600 into your TSX Micro PLC system is straightforward. The module fits into a standard rack slot and connects via two SUB-D 25 connectors. Follow these tips for a smooth installation:
- Power Down: Always de-energize the PLC before inserting or removing the module.
- Wiring: Use shielded twisted-pair cables for analog signals to minimize noise. Connect the shield to ground at one end only.
- Input Configuration: Set each channel’s input type (current or voltage) according to your sensor’s output. Refer to the module’s user manual for DIP switch or software settings.
- Grounding: Ensure proper grounding of the module and the rack to maintain the 1000 Vrms isolation integrity.
Maintenance and Reliability
The TSXAEY1600 is built for long-term industrial service. To maximize its lifespan:
- Periodic Inspection: Check all connectors and wiring for signs of corrosion or loose connections every six months.
- Environmental Control: Keep the module within its operating temperature (0 to 60°C) and humidity (10–95% non-condensing) ranges. Ensure adequate ventilation in the cabinet.
- Firmware Updates: If your PLC system supports it, keep the module’s firmware current to benefit from bug fixes and performance improvements.
Compatibility and Integration
The TSXAEY1600 is part of the Schneider Electric TSX Micro PLC family. It is designed to work seamlessly with TSX Micro programmable logic controllers, providing a native interface for analog signals. The module’s standard format ensures easy mounting in the PLC rack. For detailed integration steps, consult the product documentation or contact SpareTechPLC’s technical support.
Purchasing Guide
Before ordering the TSXAEY1600, verify the following:
- PLC Compatibility: Confirm that your TSX Micro PLC model supports this module. Check the PLC’s backplane capacity and power budget (the module draws 270 mA at 5 V DC).
- Input Signal Types: Ensure the module’s input ranges (0–20 mA, 4–20 mA, ±10 V, 0–10 V, 0–5 V, 1–5 V) match your sensors.
- Wiring Accessories: Plan for the required SUB-D 25 connectors and cabling.
SpareTechPLC offers the TSXAEY1600 with fast worldwide shipping. Our team can help you confirm compatibility and provide replacement or upgrade options if needed. Contact us today to secure your module and keep your automation running.
Frequently Asked Questions
What is the power consumption of the TSXAEY1600?
The module consumes 270 mA at 5 V DC, which is typical for a 16-channel analog input module. Ensure your PLC’s power supply can handle this additional load.
Can the TSXAEY1600 handle both current and voltage inputs on the same module?
Yes, each of the 16 channels can be individually configured for current (0–20 mA or 4–20 mA) or voltage (±10 V, 0–10 V, 0–5 V, 1–5 V) inputs, offering great flexibility.
What is the measurement accuracy of the TSXAEY1600?
The measurement error is 0.1% of full scale at 25°C for voltage ranges. This ensures high precision in your analog measurements.
Does the TSXAEY1600 provide isolation between channels?
The module provides 1000 Vrms isolation between channels and the bus, and between channels and ground. However, there is no isolation between individual channels (common point). Plan your wiring accordingly to avoid ground loops.
Is the TSXAEY1600 still in production?
Please verify current lifecycle status and availability with SpareTechPLC before ordering. We can advise on availability and suggest alternatives if needed.