When a Packaging Line Outgrows Its Legacy Controller
A mid-sized food packaging plant faced a familiar problem: its aging control cabinet handled discrete logic well, but adding analog temperature and pressure feedback required a full panel redesign. The engineering team needed a compact PLC that could accept analog signals directly, communicate over the existing serial network, and fit into the space left by the old controller. The Schneider TSX3710101 micro PLC solved that challenge without forcing a plant-wide retrofit.

What Is the TSX3710101 Micro PLC?
The TSX3710101 belongs to the Schneider Electric TSX Micro PLCs product line. It is a micro PLC engineered for versatile automation solutions across compact machinery and process skids. The unit operates within a 100-240 V AC voltage range and supports input currents from 2 mA up to 60 A. Two expansion slots let integrators add modular I/O as project demands grow.
Technical Specifications That Matter on the Floor
Analog I/O Without Extra Hardware
Eight analog input slots accept a 0 to 10 V range, and one analog output slot supports the same 0 to 10 V range. This configuration lets the controller read sensors directly and drive analog actuators without separate signal conditioners.
Communication Built for Legacy and Modern Networks
The TSX3710101 includes one serial link (TER/AUX) using Uni-Telway rated at 19.2 kbit/s, plus one Modbus RTU interface also rated at 19.2 kbit/s. That dual-path design simplifies integration with existing HMI panels and supervisory systems.
Memory and Scan Performance
Flash memory provides 15 Kwords, while internal RAM offers 20 Kwords and can be expanded to 128 Kwords with a PCMCIA card. Execution times range from 0.13 µs for Boolean operations to 4.5 µs for arithmetic REAL floating operations. The application structure supports one fast task, one master task, and sixteen event tasks.
Environmental and Physical Profile
Operating temperature spans 32-140 °F (0-60 °C), and humidity tolerance runs from 10% to 95% without condensation. The unit measures 13.44 x 5.94 x 5.98 inches and weighs 1.00 lbs (0.45 kg). It runs on 50/60 Hz power and delivers a maximum output current of 0.5 A.

Where This Micro PLC Delivers Value
Packaging and Labeling Retrofit
When a line needs analog registration or tension feedback, the eight analog inputs eliminate the cost of external signal converters. The compact footprint fits existing enclosures, which shortens downtime during changeover.
Water Treatment Skid Control
A skid builder can use the Modbus RTU port to link the PLC with variable-frequency drives and flow meters. The 0 to 10 V analog channels handle pressure transmitters directly, reducing wiring complexity.
Replacement and Upgrade Path
Plants running older TSX Micro hardware often seek a drop-in solution. The TSX3710101 keeps the same TER/AUX and Modbus RTU communication style, so migration typically involves transferring logic rather than redesigning the network. Please verify current lifecycle status and availability with SpareTechPLC before ordering.
Installation and Setup Guidance
Mount the unit inside a panel that respects the 13.44 x 5.94 x 5.98 inch envelope and leaves clearance for airflow. Confirm the supply falls within 100-240 V AC at 50/60 Hz. Route analog signal wiring away from high-voltage conductors to protect the 0 to 10 V channels. Use the TER/AUX port for programming and the Modbus RTU port for network communication. Follow Schneider Electric’s published installation manual for terminal torque and grounding.
Maintenance and Reliability Practices
Inspect the panel filter and ventilation quarterly, since the 32-140 °F (0-60 °C) rating assumes adequate airflow. Check terminal connections annually for looseness caused by thermal cycling. Keep ambient humidity within the 10% to 95% non-condensing range to prevent condensation on the circuit boards. If the application grows, add a PCMCIA card to expand internal RAM to 128 Kwords rather than replacing the controller.
Compatibility and Integration Notes
The Uni-Telway serial link and Modbus RTU interface allow connection to a wide range of Schneider Electric and third-party devices. The two expansion slots accept compatible TSX Micro I/O modules. Before purchase, confirm that your existing backplane, power supply, and terminal blocks match the TSX3710101 footprint. SpareTechPLC can help verify compatibility with your current panel layout.
Frequently Asked Questions
What analog signal range does the TSX3710101 accept?
It provides eight analog input slots and one analog output slot, both supporting a 0 to 10 V range.
Can I expand the program memory beyond 20 Kwords?
Yes. Internal RAM can be expanded to 128 Kwords using a PCMCIA card.
Which communication protocols does this PLC support?
It offers one serial link (TER/AUX) with Uni-Telway at 19.2 kbit/s and one Modbus RTU interface at 19.2 kbit/s.
What is the maximum output current?
The unit delivers a maximum output current of 0.5 A.
What operating temperature range should I plan for?
The PLC operates between 32-140 °F (0-60 °C) with humidity from 10% to 95% without condensation.