Introduction
Industry has evolved from relay banks to smart, connected machines. The LMC058LF42S0 sits at that turning point. It is a Modicon LMC058 logic controller from Schneider Electric, built for deterministic control in compact machines. This model carries 42 I/O and a dual-core ARM Cortex-A8 processor. It runs logic-only tasks with no motion axes activated. That focus makes it a strong fit for OEMs that need fast scan cycles without servo control. Because Schneider has set an end-of-sale date, this controller now serves two audiences: plants that still run it and engineers planning a controlled migration.

Key Technical Specifications
The LMC058LF42S0 pairs a dual-core ARM Cortex-A8 processor with 128 MB Flash program memory and 64 MB RAM. A 22 ns scan speed per Boolean instruction keeps logic execution tight, which matters when cycle time drives throughput. The unit provides 26 digital inputs (10 fast, 12 regular, 4 configurable) and 16 digital outputs (12 regular, 4 fast). Four fast outputs support pulse functions, and fast inputs feed integrated high-speed counters. There are no analog channels on this variant. Up to seven TM5 expansion modules can extend the I/O count when the base rack runs out of points.
| Specification | Value |
|---|---|
| Brand / Series | Schneider Electric / Modicon LMC058 |
| Processor | Dual-core ARM Cortex-A8 (M258 platform) |
| Program / Data memory | 128 MB Flash / 64 MB RAM |
| Scan speed | 22 ns per Boolean instruction |
| Digital inputs | 26 (10 fast + 12 regular + 4 configurable) |
| Digital outputs | 16 (12 regular + 4 fast) |
| Analog I/O | None |
| Communication ports | 1× Ethernet RJ45, 1× serial RS-232/RS-485, 2× CAN (SUB-D9), 1× encoder input (SUB-D15), 1× USB-B mini, 1× USB-A |
| Protocols | Modbus TCP/IP, Modbus RTU/ASCII, CANopen master, CANmotion master |
| Supply voltage | 24 V DC (20.4…28.8 V) |
| Power consumption | 13.03 W |
| Operating temperature | 0…+55 °C |
| Protection rating | IP20 |
| Dimensions (H×W×D) | 175 × 99 × 85 mm |
| Weight | 0.55 kg |
A Replacement and Upgrade Guide
Schneider lists the LMC058LF42S0 as discontinued, with end-of-sale on 2026-06-30 and service end on 2031-06-30. That timeline creates a clear planning window. If your line depends on this controller, you have two paths. First, stock spare units to cover the remaining service life. Second, design a migration to the recommended replacement, the Modicon M262 or LMCever family. The M262 offers a modern platform, but it is not a drop-in swap. You must re-verify I/O count, communication ports, and program conversion. Because the LMC058LF42S0 uses SoMachine or EcoStruxure Machine Expert for programming, your existing project files give you a starting point for the new target. SpareTechPLC can help you compare availability and lead times before you commit.

Where It Fits on the Plant Floor
Three scenarios show the value of this controller. In packaging, the 22 ns scan speed and fast I/O handle registration and cut-to-length logic without jitter. In material handling, the CANopen master port coordinates drives and remote I/O over a single cable. In building automation, the Ethernet port supports Modbus TCP/IP for supervisory data, while the serial port links legacy meters. Each case uses the logic-only design to keep cost and complexity down. The absence of analog channels is not a limitation here; it is a signal that this model targets discrete control, not process loops.
Installation and Setup Notes
The LMC058LF42S0 mounts on a symmetrical DIN rail, and its 175 × 99 × 85 mm housing fits standard enclosures. Wire the 24 V DC supply within the 20.4…28.8 V range and respect the 0.28 A rated main supply current. Keep the cabinet at IP20 cleanliness and maintain 0…+55 °C operating temperature. Route encoder cable to the SUB-D15 port using the specified 5 V differential RS-422 interface. For programming, connect the USB-B mini port or use Ethernet. Follow Schneider’s installation manual for grounding and separation of power and signal wiring.
Maintenance and Long-Term Reliability
Inspect the controller periodically for loose terminals, dust buildup, and fan-free cooling paths. The CR2477M lithium battery protects the real-time clock and data retention; replace it on a scheduled interval to avoid memory loss. Because the product is discontinued, treat every spare as a long-term asset. Store units within -25…+70 °C and 10…95% non-condensing humidity. If you plan to run past 2031, start your migration project now. SpareTechPLC can advise on current stock and replacement options.
Compatibility and Integration
The LMC058LF42S0 speaks Modbus TCP/IP over Ethernet, Modbus RTU/ASCII over serial, and CANopen or CANmotion master over CAN. It also supports optional PCI communication modules for SERCOS III and additional networks. This range lets it act as a data concentrator or as a peer in a larger control system. Before you integrate, confirm that your HMI, drives, and remote I/O use one of these protocols. The encoder input accepts incremental signals, which suits speed feedback or position tracking without a separate card.
Frequently Asked Questions
Is the LMC058LF42S0 still available?
Schneider has discontinued this model. End-of-sale is 2026-06-30, and service ends 2031-06-30. Contact SpareTechPLC to check current stock and lead times.
Can I use the LMC058LF42S0 for motion control?
No. This is the logic-only variant with 0 axes. The motion option is not activated. For motion, look at other LMC058 models or the recommended M262 family.
What software programs the LMC058LF42S0?
You can use SoMachine or EcoStruxure Machine Expert. Existing projects can be opened and modified in these environments.
How many expansion modules can I add?
You can add up to seven TM5 expansion modules to the base controller.
What is the recommended replacement?
Schneider recommends the Modicon M262 or LMCever family. Plan for I/O and protocol mapping before you migrate.
Selection Checklist
Before you buy, verify your I/O count, protocol needs, and supply voltage. Confirm that 26 digital inputs and 16 digital outputs cover your machine, and that you do not need analog channels. Check that your network uses Modbus TCP/IP, Modbus RTU/ASCII, or CANopen. If you need more points, plan for TM5 expansion modules. Finally, confirm lifecycle status and availability with SpareTechPLC. As a supplier of industrial automation parts, SpareTechPLC can help you secure the LMC058LF42S0 or plan a transition to a supported platform.