IC695PBS301 | GE PROFIBUS Slave Module for RX3i PacSystems

Contact for Price Fast reply within 24 hours

GE IC695PBS301 PROFIBUS slave module for RX3i PacSystems. Supports 244-byte I/O, DP-V1, 9-pin connector, and universal backplane compatibility.

Product Description

Is Your Control System Struggling to Integrate Legacy Devices with Modern PROFIBUS Networks?

Many plant engineers face a common challenge: integrating older field devices into a modern PROFIBUS DP network without replacing the entire control architecture. The GE Fanuc IC695PBS301 PROFIBUS slave module solves this problem. It is a single-slot module designed for the RX3i PacSystems series. This module provides reliable slave communication over PROFIBUS DP networks. It exchanges data with a master device automatically, acknowledging received messages and transmitting data when requested.

Figure 1: Front view of the GE IC695PBS301 industrial automation component showing its physical design and enclosure.

What Is the IC695PBS301?

The IC695PBS301 is a PROFIBUS slave module manufactured by GE Intelligent Platforms. It belongs to the RX3i PacSystem product line under the IC695 catalog. This module supports universal backplane compatibility, specifically the RX3i PCI backplane. It features a 9-pin connector and consumes 440 mA at 3.3 V DC. The module includes three LED indicators: PROFIBUS OK, NETWORK, and MOD STATUS. These LEDs provide immediate visual feedback on power, communication, and module health.

Key Technical Specifications

The IC695PBS301 offers robust features for industrial automation. It supports all standard PROFIBUS data rates. The module can read input data loads up to 244 bytes and transmit output data loads up to 244 bytes. It also supports DP-V1 Read-Write and Alarms messages. The operating temperature range is 0 to 60 degrees Celsius, while storage temperature ranges from -40 to 85 degrees Celsius. Firmware upgrades are handled indirectly through the host controller CPU using the WinLoader software utility.

LED Indicators and Diagnostics

The green PROFIBUS OK LED indicates power presence and a complete backplane reset. The yellow bicolor NETWORK LED shows that the module can transmit PROFIBUS telegrams; it turns red if critical communication problems occur. The bicolor MOD STATUS LED displays the module’s operating status. These indicators simplify troubleshooting and reduce downtime.

Figure 2: Technical layout and connection details for the GE IC695PBS301 industrial automation component.

Why Choose the IC695PBS301 for Your RX3i System?

This module is an excellent replacement or upgrade for existing PROFIBUS slave interfaces. It integrates seamlessly with RX3i PCI backplanes. The universal backplane support means you can deploy it across different RX3i configurations without compatibility worries. The 244-byte input and output data loads handle substantial process data. DP-V1 Read-Write and Alarms messages enable advanced diagnostics and parameterization. The WinLoader utility simplifies firmware updates through the CPU, eliminating the need for direct module programming.

Installation and Setup

Installing the IC695PBS301 is straightforward. Insert the module into a single slot on the RX3i PCI backplane. Connect the PROFIBUS network cable to the 9-pin connector. Ensure the operating temperature remains between 0 and 60 degrees Celsius. Verify that the backplane supports universal compatibility. After power-up, check the LED indicators: green PROFIBUS OK confirms power and reset; yellow NETWORK indicates active telegram transmission; and MOD STATUS shows normal operation. For firmware updates, use the WinLoader software utility through the host controller CPU.

Maintenance and Reliability

The IC695PBS301 requires minimal maintenance. Periodically inspect the LED indicators for abnormal states. A red NETWORK LED signals critical communication problems. Clean the module exterior with a dry cloth when needed. Avoid exposing the module to temperatures outside the storage range of -40 to 85 degrees Celsius. Regular firmware updates via WinLoader ensure optimal performance. The module’s robust design and universal backplane support make it a reliable long-term investment for your RX3i system.

Compatibility and Integration

The IC695PBS301 works exclusively with RX3i PacSystems. It communicates over PROFIBUS DP networks. The module supports all standard PROFIBUS data rates. It exchanges data with a master device automatically. The 9-pin connector is standard for PROFIBUS installations. The module does not have bus access rights but acknowledges received messages and transmits to the master when requested. This design ensures deterministic communication in master-slave architectures.

Frequently Asked Questions

What is the power consumption of the IC695PBS301?

The module consumes 440 mA at 3.3 V DC.

What LED indicators does the IC695PBS301 have?

It has three LEDs: PROFIBUS OK (green), NETWORK (yellow/red bicolor), and MOD STATUS (bicolor).

Can the IC695PBS301 handle large data loads?

Yes, it supports up to 244 bytes of input data and 244 bytes of output data.

How are firmware updates performed?

Firmware upgrades occur indirectly through the host controller CPU using the WinLoader software utility.

What is the operating temperature range?

The module operates between 0 and 60 degrees Celsius and stores between -40 and 85 degrees Celsius.