Schneider

iC60N 2P C32 | Schneider 32A 2-Pole MCB

  • Model iC60N 2P C32
  • Condition In Stock
4.6/5 (16 reviews)
$224.00 Indicative price · request a quote for availability

Schneider Electric Acti9 iC60N 2P C32 miniature circuit breaker: 32A, C-curve, 6 kA breaking capacity, 400V AC / 125V DC, DIN rail mount.

Product Description

Buyer’s Guide: Is the Schneider iC60N 2P C32 Right for Your Panel?

Specifying the wrong breaker costs more than the part itself. A mismatched curve trips on motor inrush, a low breaking capacity fails under fault, and an oversized device leaves conductors unprotected. The Schneider Electric iC60N 2P C32 removes that guesswork: it is a 32 A, two-pole miniature circuit breaker from the Acti9 iC60 series, built for 400 V AC and 125 V DC circuits on standard 35 mm DIN rail.

This guide walks through what the device does, where it fits, and what to confirm before you buy.

Figure 1: Front view of the Schneider iC60N 2P C32 industrial automation component showing its physical design and enclosure.

What the Acti9 iC60 Series Delivers

The iC60N is the standard breaking-capacity tier of Schneider’s Acti9 iC60 range. This model carries a 6 kA rating at 230/400 V under IEC 60898-1, so it clears fault currents typical of final distribution boards and sub-panels. It also conforms to IEC 60947-2, which lets designers apply it in industrial control assemblies as well as commercial installations.

Two poles matter here. A 2P device opens both the phase and neutral conductors together, which suits single-phase final circuits and DC applications where both legs need isolation. The 32 A rating matches common 4 mm² to 6 mm² final circuits, and the C-curve magnetic trip at 8×In ±20% tolerates brief inrush from small motors, transformers, and LED drivers without nuisance tripping.

Key Specifications at a Glance

Parameter Value
Poles 2P
Rated current 32 A
Trip curve C (thermal-magnetic, 8×In ±20%)
Breaking capacity 6 kA @ 230/400 V (IEC 60898-1)
Rated voltage 400 V AC, 125 V DC
Standards EN/IEC 60898-1, EN/IEC 60947-2
Operating temperature -35 to 70 °C
Mounting 35 mm DIN rail
Mechanical life 20,000 cycles
Electrical life 10,000 cycles
Dimensions (H×W×D) 85 × 36 × 78.5 mm
Weight 0.25 kg

What the Numbers Mean in Practice

The 6 kA breaking capacity tells you the device can interrupt a short-circuit current up to 6,000 A at 230/400 V. In most commercial distribution boards, prospective fault current sits well below that figure, so the iC60N 2P C32 covers the majority of final-circuit protection duties.

The C-curve is the practical detail buyers overlook. Thermal-magnetic operation means a thermal element handles overloads and a magnetic element handles short circuits. With the magnetic threshold at 8×In, this breaker rides through the starting current of small inductive loads. Choose a B-curve instead and you may chase nuisance trips; choose a D-curve and you may slow fault clearance.

Operating Range and Service Life

The -35 to 70 °C operating window covers unheated plant rooms and outdoor cabinets in most temperate and cold climates. Mechanical life of 20,000 cycles and electrical life of 10,000 cycles set realistic expectations: this is a device for switching and protection duty, not for frequent manual isolation.

Figure 2: Technical layout and connection details for the Schneider iC60N 2P C32 industrial automation component.

Where This Breaker Fits

Commercial sub-distribution. A 32 A, two-pole C-curve device protects single-phase final circuits feeding socket outlets, lighting sub-circuits, and small HVAC loads. The 6 kA rating aligns with typical board-level fault levels.

Industrial control panels. IEC 60947-2 conformity makes the iC60N 2P C32 suitable for machine control assemblies, where it can protect control transformers and small drive circuits. The 125 V DC rating extends its use to DC control supplies.

Replacement and upgrade work. Because the Acti9 iC60 range remains in active production, this model is a straightforward drop-in for failed devices of the same rating. Matching poles, current, and curve is the critical step.

Installation Notes

Mount the device on 35 mm DIN rail and confirm the busbar or cable entry matches the 2P configuration. Verify the supply voltage against the 400 V AC or 125 V DC rating before energizing. Torque terminations to the manufacturer’s specification and confirm the circuit’s prospective fault current does not exceed the 6 kA rating. Follow local wiring regulations and the manufacturer’s instructions throughout.

Maintenance and Long-Term Reliability

Inspect periodically for discoloration, loose terminations, and mechanical damage. In dusty or humid environments, check the enclosure and clean only as permitted by site procedures. Track trip events: repeated tripping under normal load points to an overload or a failing load, not a faulty breaker. With 10,000 electrical cycles available, planned replacement intervals are long, which keeps total cost of ownership low.

What to Verify Before You Order

Confirm four things: pole count (2P), rated current (32 A), trip curve (C), and breaking capacity (6 kA). Check that your panel accepts 35 mm DIN rail and that the 36 mm width fits your available space. If you are replacing an existing device, match the original rating exactly. SpareTechPLC supplies this model and can confirm current lifecycle status and availability before you commit.

Frequently Asked Questions

What does the C-curve on this breaker mean?

The C-curve uses a thermal-magnetic trip with a magnetic threshold at 8×In ±20%, which tolerates brief inrush currents from small motors and transformers.

Can I use the iC60N 2P C32 on a DC circuit?

Yes. The rated voltage includes 125 V DC, alongside 400 V AC.

How much panel width does it need?

The device measures 36 mm wide and mounts on standard 35 mm DIN rail.

Is this model still in production?

Yes. The Acti9 iC60 range is listed as active, last verified in September 2026. Confirm availability with SpareTechPLC before ordering.

Specifications

Model / No. iC60N 2P C32
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $224.00

Additional Information

Schneider Electric Acti9 iC60N 2P C32 miniature circuit breaker: 32 A, two-pole, C-curve, 6 kA breaking capacity at 230/400 V, 400 V AC / 125 V DC rated voltage, 35 mm DIN rail mounting. Active in production. Verify availability with SpareTechPLC.

Shipping & Returns

Shipping Port
Xiamen

Downloads

Download Instruction Manual (iC60N202P20C32.pdf)

Latest News

View All News