Product Overview
When a single final circuit trips without warning, production stops and every minute of downtime costs money. The iC60N 1P C10 from Schneider Electric solves that problem at the source. It is a single-pole miniature circuit breaker from the Acti9 iC60 series, rated 10A with a C trip curve. Maintenance engineers choose it because it protects one circuit, mounts on standard 35 mm DIN rail, and swaps out in minutes.
This breaker carries a 6 kA breaking capacity at 230/400V AC and also handles 125V DC. It meets EN/IEC 60898-1 and EN/IEC 60947-2, so it fits both residential distribution and industrial control panels. The lifecycle status is active, confirmed in the Acti9 range as of September 2026.

Key Parameters That Matter on the Floor
10A Rating and C-Curve Trip
The 10A rated current suits lighting, socket, and small motor circuits. The C curve uses thermal-magnetic protection with a magnetic trip at 8×In ±20%. That means it tolerates brief inrush currents from small motors or transformers without nuisance tripping. For a maintenance engineer, fewer false trips mean fewer call-outs.
6 kA Breaking Capacity
A 6 kA breaking capacity at 230/400V AC gives solid short-circuit protection in most commercial and light industrial boards. It clears faults safely and keeps the fault contained. Always confirm your panel’s prospective fault current stays below this value.
1P Format and DIN Rail Mounting
The single-pole design saves space in dense distribution boards. It clips onto 35 mm DIN rail, so replacement takes minutes, not hours. Dimensions are 85 × 18 × 78.5 mm and weight is 0.125 kg.
Long Service Life
Mechanical life reaches 20,000 cycles and electrical life reaches 10,000 cycles. In a typical panel, that covers years of switching operations before replacement is needed.
Where This Breaker Fits
Panelboard Upgrades and Replacements
Angle D applies here: this is a direct replacement part. When an older 10A single-pole breaker fails, the iC60N 1P C10 drops into the same 35 mm DIN rail slot. No re-engineering, no new enclosure. That shortens planned maintenance windows and cuts labour cost.
Control Panel Branch Protection
Machine builders use 10A C-curve breakers to protect control transformers and small drives. The C curve absorbs start-up surges while still tripping on real faults. The wide operating temperature range of -35 to 70 °C supports cabinets in hot or cold plants.
DC Auxiliary Circuits
The 125V DC rating allows use in DC control and auxiliary supply circuits. This gives one part number coverage across AC and DC duties, which simplifies spares holding.
Installation and Setup
Mount the breaker on a 35 mm DIN rail and confirm the rail clip locks fully. Verify the circuit’s rated current does not exceed 10A. Check that the supply voltage matches 230/400V AC or 125V DC. Torque terminations to the value stated in the Schneider Electric installation instructions. Never work on a live circuit. Follow local wiring regulations and the manufacturer’s manual at all times.
Maintenance and Reliability
From a service perspective, this breaker needs little attention. Inspect terminals periodically for looseness or discolouration. Check for signs of overheating after high-load periods. Test the trip mechanism during scheduled shutdowns. Keep the panel free of dust and moisture. Because the unit is active in the Acti9 range, spare availability is strong, which protects your long-term maintenance budget.
Compatibility and Integration
This breaker shares the Acti9 iC60 footprint, so it fits standard 35 mm DIN rail enclosures and distribution boards. It works alongside other Acti9 protective devices in the same panel. Confirm busbar and comb compatibility with your existing Acti9 installation before ordering.
Selection Guide
Before you buy, verify four things: rated current (10A), trip curve (C), poles (1P), and breaking capacity (6 kA). Confirm your fault level and voltage. If you need a different rating or curve, check the wider Acti9 iC60 range. SpareTechPLC stocks industrial automation parts and can confirm availability quickly.
Frequently Asked Questions
See the FAQ section below for model-specific answers on ratings, replacement, and lifecycle.
Please verify current lifecycle status and availability with SpareTechPLC before ordering.