Schneider

BMXDAI0805 | Schneider 8-Channel AC Input Module

  • Model BMXDAI0805
  • Type I/O Modules
  • Condition In Stock
4.6/5 (16 reviews)
$266.00 Indicative price · request a quote for availability

Schneider BMXDAI0805 Modicon X80 discrete AC input module with 8 channels, 200-240 V AC range, and channel-to-channel isolation.

Product Description

Why the BMXDAI0805 Belongs in Your Spares Budget

Downtime on a Modicon M340 or M580 rack rarely comes from the processor. It comes from a single I/O card that stops reading field signals. The Schneider BMXDAI0805 is the 8-channel discrete AC input module built for exactly that risk. It sits in the Modicon X80 family, a shared I/O platform for both M340 and M580 controllers, so one spare covers multiple racks on your site.

That shared-platform design is the first cost argument. Instead of stocking separate cards for each controller family, you hold one BMXDAI0805 and cover both. Fewer part numbers on the shelf means less capital tied up in inventory and a faster swap when a line goes down.

Figure 1: Front view of the Schneider BMXDAI0805 industrial automation component showing its physical design and enclosure.

Technical Specifications That Drive Cost Per Point

Eight Channels on One Card

The module reads eight discrete AC inputs at 200-240 V AC, with an operating range of 170-264 V AC at 50/60 Hz. Field devices connect through a 20-pin terminal block. Eight points per card lowers your cost per I/O point and reduces the number of slots consumed in the rack.

Channel-to-Channel Isolation

Each channel is isolated from the others. A fault on one field circuit does not drag down its neighbors. In practice, this limits the blast radius of a single wiring fault and protects the rest of the process from a forced stop. That is direct avoided downtime, not just a datasheet line.

Low Current Draw, Predictable Power Budget

Input current is 10.4 mA per channel, and the module consumes 4.73 W. Bus current is 60 mA at 24 V DC. These figures let you size power supplies and cabinet cooling accurately, so you avoid overspending on oversized power hardware.

Filtering and Diagnostics

The input filter is 10 ms ON and 20 ms OFF. That filtering rejects contact bounce and electrical noise on long field runs, which reduces nuisance trips. Per-channel LEDs plus module ERR and I/O LEDs let a technician identify a bad point in seconds rather than tracing wires for an hour.

Environmental and Physical Fit

The module operates from 0°C to +60°C and stores from -25°C to +70°C, with 5% to 95% relative humidity, non-condensing. Protection rating is IP20. It measures 100 × 28 × 93 mm and weighs 0.12 kg. The compact footprint frees panel space and keeps cabinet layout flexible.

Reliability You Can Budget Against

MTBF is 1,700,000 h. That number supports a planned replacement strategy instead of reactive buying. You can schedule spares purchasing around realistic service life rather than emergency pricing.

Where the BMXDAI0805 Earns Its Place

Water and Wastewater Pump Control

Pump run-status and float switch signals often arrive as 200-240 V AC. The wide 170-264 V AC operating range tolerates supply sag without dropping a status input. Stable status reading means fewer false alarms and less operator intervention.

Packaging and Material Handling

Conveyor photo-eyes and limit switches feed discrete AC signals into the rack. Channel-to-channel isolation keeps one damaged sensor cable from taking out adjacent inputs, so a single fault does not stop the whole line.

Legacy Panel Retrofit

When replacing an older AC input card, the shared X80 platform lets you standardize on one module type across M340 and M580 racks. Standardization cuts training time and spare-part count, which lowers total cost of ownership.

Figure 2: Technical layout and connection details for the Schneider BMXDAI0805 industrial automation component.

Installation and Setup Notes

Mount the module in a Modicon X80 rack and wire field devices to the 20-pin terminal block. Keep AC field wiring separated from low-level signal cabling to reduce induced noise. Confirm the supply voltage falls within the 170-264 V AC operating range before commissioning. Verify rack power budget against the 60 mA bus current at 24 V DC and the 4.73 W module consumption. Follow the manufacturer’s installation manual for torque and wiring practice.

Maintenance and Long-Term Cost Control

Inspect the module periodically and confirm LED status matches actual field conditions. Check terminal connections for looseness during scheduled shutdowns. Keep the cabinet within the 0°C to +60°C operating range and maintain non-condensing humidity. Because MTBF is 1,700,000 h, a scheduled spare on the shelf is cheaper than an emergency purchase. One spare BMXDAI0805 covering both M340 and M580 racks is the simplest cost-control move available.

Compatibility and Integration

The module belongs to the Modicon X80 series and works within M340 and M580 architectures. It connects through a 20-pin terminal block and communicates over the rack backplane. Confirm your controller platform and rack type before ordering.

Selection Checklist Before You Buy

Verify your field signal voltage sits within 200-240 V AC and that eight channels match your point count. Confirm the 20-pin terminal block is available or already fitted. Check that your rack has slot space and power headroom. Please verify current lifecycle status and availability with SpareTechPLC before ordering. The lifecycle is listed as active on the shared M340 and M580 I/O platform, last verified 2026-09.

Frequently Asked Questions

Does the BMXDAI0805 work with both M340 and M580 controllers?

Yes. It is part of the Modicon X80 shared I/O platform used across both controller families.

How many field devices can I connect?

Eight discrete AC input channels, wired through a single 20-pin terminal block.

What input voltage does it accept?

200-240 V AC nominal, with an operating range of 170-264 V AC at 50/60 Hz.

How does isolation reduce my operating cost?

Channel-to-channel isolation stops one field fault from affecting other channels, which limits unplanned downtime.

What is the MTBF and why does it matter?

MTBF is 1,700,000 h, which supports planned spare stocking instead of emergency purchasing.

Specifications

Model / No. BMXDAI0805
Product Type I/O Modules
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $266.00

Additional Information

Schneider Electric BMXDAI0805 Modicon X80 discrete AC input module: 8 channels, 200-240 V AC (170-264 V AC range), channel-to-channel isolation, 10.4 mA per channel, 4.73 W, 20-pin terminal block, MTBF 1,700,000 h. Active on the shared M340 and M580 I/O platform.

Shipping & Returns

Shipping Port
Xiamen

Downloads

Download Instruction Manual (BMXDAI0805.pdf)