Introduction to the Schneider 170FNT11001 FIPIO Module
Maintenance engineers know that network reliability starts with the right communication hardware. The Schneider Electric 170FNT11001 is a FIPIO communication module built for the Modicon Momentum automation platform. It handles data exchange over FIPIO protocol at a transmission rate of 1 Mbit/s. This module draws supply directly from the I/O base, which simplifies wiring and reduces cabinet clutter. With CE marking and a lightweight design of 0.11 kg, it fits neatly into existing control architectures.

Technical Specifications That Matter on the Floor
Three parameters drive daily performance for the 170FNT11001. First, the 1 Mbit/s transmission rate supports responsive data sharing across connected devices. Second, the cable length range of 1000 to 5000 meters gives layout flexibility across large plants. Third, the fail state options — maintain value or fallback to zero — protect process integrity when communication drops. The module also supports optical fiber 50/125, optical fiber 62.5/125, and shielded twisted pairs. Each segment handles 0 to 31 devices without a repeater, or 0 to 97 devices with a repeater. The producer/consumer access method keeps data exchange efficient.
Where the 170FNT11001 Fits in Your Plant
Automotive Assembly Line Retrofit
A maintenance team upgrading an older Modicon Momentum line can drop in the 170FNT11001 to extend FIPIO network reach. The 5000 m maximum cable distance covers long conveyor runs without extra hardware. The fallback-to-zero fail state stops actuators from holding dangerous positions during faults.
Water Treatment Network Expansion
When a treatment plant adds remote pump stations, the 170FNT11001 supports tap-off or extension topology. Engineers can run shielded twisted pairs to new segments. The 1 Mbit/s rate keeps valve and sensor data flowing to the PLC without noticeable lag.
Packaging Line Replacement Planning
Angle D applies here: replacing an aging FIPIO adapter. The 170FNT11001 works with Premium bus manager PLCs. Its optical fiber support means you can isolate noisy servo drives from the communication path. This reduces electromagnetic interference issues that plague copper-only networks.

Installation and Setup Notes
Mount the module on the I/O base and confirm the supply connection. No separate power wiring is needed because the module draws from the base. For optical fiber, use 50/125 or 62.5/125 cable. For shielded twisted pairs, verify segment device counts before powering up. Keep cable runs within the 1000 to 5000 meter range. Follow the manufacturer’s safety manual for all wiring and configuration steps. The CE marking confirms compliance with relevant regulatory standards.
Maintenance and Reliability for Service Teams
Inspect the module periodically for loose connections and dust buildup on optical ports. Check segment device counts if you add or remove nodes. The producer/consumer access method means one faulty device can affect data sharing, so test new devices on a bench first. The 0.11 kg weight and compact package make swap-outs quick during planned outages. Store spare units in original packaging to protect optical interfaces. Environmental protection treatment TC helps resist typical control cabinet conditions.
Compatibility and Integration Checklist
The 170FNT11001 integrates with Modicon Momentum and Premium bus manager PLCs. It uses the FIPIO protocol exclusively. Verify that your existing network uses FIPIO before ordering. The module supports optical fiber and shielded twisted pairs, so mixed media segments are possible. Devices per segment range from 0 to 31 without a repeater and 0 to 97 with a repeater. Plan repeater placement if your network exceeds 31 nodes. The EAN 3389110896527 helps confirm you receive the correct unit.
Selection Guide for Buyers
Before purchasing, confirm your PLC supports FIPIO communication. Check that your cable type matches either optical fiber or shielded twisted pairs. Count devices per segment and decide if a repeater is needed. Verify the 1000 to 5000 meter cable length suits your facility layout. SpareTechPLC stocks this module and can help verify current lifecycle status and availability. Contact SpareTechPLC for replacement options if this module is discontinued in your region.
Frequently Asked Questions
What is the maximum cable distance for the 170FNT11001?
The module supports cable lengths from 1000 to 5000 meters, with a maximum cable distance of 5000 meters.
How many devices can I connect per segment?
You can connect 0 to 31 devices without a repeater, or 0 to 97 devices with a repeater.
What fail state options does this module offer?
It offers maintain value and fallback to zero, helping protect system integrity during interruptions.
Does the 170FNT11001 require a separate power supply?
No, it draws supply from the connected I/O base.
What cable types are compatible?
The module works with optical fiber 50/125, optical fiber 62.5/125, and shielded twisted pairs.
Ordering the 170FNT11001
This Schneider Electric module ships as a single unit with package dimensions of 5.5 cm height, 18.0 cm width, and 26.0 cm length. Package weight is 185.0 g. The GTIN 3389110896527 confirms product identity. SpareTechPLC provides industrial automation parts and news for maintenance teams. Verify current lifecycle status and availability with SpareTechPLC before ordering.