Schneider

170ADM35010 | Schneider 16-In/16-Out 24V DC I/O Base

  • Model 170ADM35010
  • Condition In Stock
4.6/5 (16 reviews)
$263.00 Indicative price · request a quote for availability

Schneider 170ADM35010 Modicon Momentum discrete I/O base: 16 inputs and 16 outputs at 24 V DC, 5 A peak, TC protection.

Product Description

Product Overview

Downtime on a discrete production line often traces back to a failed I/O base. The 170ADM35010 from Schneider Electric is a Modicon Momentum discrete I/O base that keeps 16 input and 16 output channels in one compact housing. This replacement-and-upgrade guide explains exactly what the module offers and how to plan a swap without guesswork.

Figure 1: Front view of the Schneider 170ADM35010 industrial automation component showing its physical design and enclosure.

Technical Specifications

The 170ADM35010 runs on 24 V DC for both discrete inputs and discrete outputs, with output voltage allowed up to 30 V DC. Both input and output logic are positive, so standard sourcing field devices and positive-logic control wiring apply. The module supports solid-state switch outputs and delivers a peak output current of 5 A, enough for many inductive and lamp loads on a single channel. Input resistance is 4 kOhm.

Channel architecture is split into three groups: two groups of eight outputs and one group of 16 inputs. Sixteen LEDs show channel status for fast fault finding. Isolation between channels and the bus is rated 500 V AC, which helps protect the backplane from field transients.

The unit measures 5.6 in (141.5 mm) high, 4.9 in (125 mm) wide, and 1.9 in (47.5 mm) deep, with a net weight of 0.4 lb (0.2 kg). It carries TC protective treatment and a CE marking. Operating temperature spans 0°C to 60°C, storage spans -40°C to 85°C, and maximum relative humidity is 95% without condensation. A known fault type is overload on output.

Replacement and Upgrade Fit

When a legacy I/O base fails, engineers need a drop-in solution rather than a redesign. The 170ADM35010 belongs to the Modicon Momentum automation platform, so it slots into existing Momentum racks and preserves the original channel count and grouping. Because the output groups are arranged as two blocks of eight, you can replace a failed base without re-addressing every point in the cabinet.

Before ordering, confirm the host controller and rack accept the Momentum platform. Also check that field wiring matches positive logic on both inputs and outputs. The 500 V AC channel-to-bus isolation supports mixed cabinets where drives and relays sit nearby.

Figure 2: Technical layout and connection details for the Schneider 170ADM35010 industrial automation component.

Where It Performs Best

Discrete manufacturing cells use the 170ADM35010 to read limit switches, pushbuttons, and proximity sensors on 24 V DC inputs, then drive solenoids, indicator lamps, and small contactors on the outputs. The 5 A peak output current covers many of these loads directly.

Packaging and material-handling lines benefit from the grouped outputs. Two groups of eight outputs let you split motor starters from diverter solenoids, simplifying troubleshooting when one group trips on overload. The 16 LEDs make that diagnosis quick.

Outdoor or washdown-adjacent cabinets are viable when humidity stays below 95% without condensation and the ambient temperature stays within 0°C to 60°C. TC protective treatment adds a layer of resilience in these environments.

Installation Notes

Mount the base in the Momentum rack and secure field wiring to the designated input and output terminals. Keep power terminals for positive and negative supply separate from signal terminals. Route input wiring away from output and power conductors to reduce induced noise.

Verify supply polarity before energizing. Positive logic means the input and output circuits expect the documented polarity; reversing it can damage channels. After power-up, confirm all 16 channel LEDs respond correctly during a functional test.

Maintenance and Reliability

Inspect terminal torque and LED behavior during scheduled shutdowns. Overload on output is a listed fault type, so check output loads for short circuits or excessive inrush if a channel drops out. Keep cabinet filters clean to hold humidity and temperature within the rated window.

Because the module uses solid-state switch outputs, there are no mechanical contacts to wear. That reduces long-term maintenance cost compared with relay-based alternatives. Please verify current lifecycle status and availability with SpareTechPLC before ordering.

Buyer Checklist

Confirm the part number 170ADM35010, the 24 V DC input and output requirement, and the positive logic scheme. Check that your rack supports the Modicon Momentum platform. SpareTechPLC supplies industrial automation parts and can confirm stock, country of origin, and packaging details for this unit.

Specifications

Model / No. 170ADM35010
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $263.00

Additional Information

Schneider 170ADM35010 Modicon Momentum discrete I/O base with 16 inputs and 16 outputs at 24 V DC, positive logic, 5 A peak output current, TC protective treatment, and CE marking. Verify lifecycle status and availability with SpareTechPLC.

Shipping & Returns

Shipping Port
Xiamen

Downloads

Download Instruction Manual (Schneider_E696BDE88090E5BEB7_170ADM35010_Service_Manual.pdf)

Latest News