Schneider

TCSEGDB23F24FA | Schneider Modbus Plus Gateway

  • Model TCSEGDB23F24FA
  • Condition In Stock
4.6/5 (16 reviews)
$253.00 Indicative price · request a quote for availability

Schneider Electric ConneXium TCSEGDB23F24FA Modbus Plus proxy module bridges Modbus TCP Ethernet to Modbus Plus with up to 128 slaves. Active lifecycle.

Product Description

Why This Gateway Belongs in Your Upgrade Plan

Maintenance engineers know the pain: a legacy Modbus Plus network still runs critical machinery, yet the control layer has moved to Ethernet. The TCSEGDB23F24FA from Schneider Electric solves that mismatch. As part of the ConneXium range, this Modbus Plus proxy module acts as a communication gateway between Ethernet Modbus TCP and Modbus Plus. It keeps older devices productive without a full rip-and-replace.

What the Module Actually Does

The unit supports Ethernet Modbus TCP to Modbus Plus protocol conversion. It carries 2 x RJ45 Ethernet TCP/IP ports for Modbus TCP and 2 x SUB-D9 ports for Modbus Plus. That dual-port layout lets you segment traffic or create a redundant path. The gateway handles up to 128 slaves, so a single module can front a substantial network of legacy nodes.

Key Specifications at a Glance

Parameter Value
Model TCSEGDB23F24FA
Brand / Series Schneider Electric / ConneXium
Product type Modbus Plus proxy module (communication gateway)
Ports 2 x RJ45 Ethernet TCP/IP (Modbus TCP) + 2 x SUB-D9 (Modbus Plus)
Protocol support Ethernet Modbus TCP to Modbus Plus
Number of slaves Up to 128
Communication services Modbus TCP messaging, Modbus Plus messaging, FDR, SNMP, Global Data, Peer cop dialogue
Platform Modicon M340 automation platform
Current consumption 300 mA at 24V DC external
Lifecycle Active (in production, ConneXium range)

Built for the Modicon M340 Platform

The module slots into the Modicon M340 automation platform. That platform focus matters for upgrade planning. If your plant already runs M340 racks, this gateway integrates without a separate communication processor. It also supports FDR, SNMP, Global Data, and Peer cop dialogue. Those services give you file transfer, network monitoring, and peer-to-peer data exchange across the combined network.

Where It Earns Its Keep

Consider a water treatment plant with Modbus Plus flow meters and a new Ethernet SCADA layer. The TCSEGDB23F24FA lets the SCADA system poll those meters through Modbus TCP messaging. No meter replacement needed. In a packaging line, the gateway can link older Modbus Plus drives to an M340 controller running Ethernet. The 128-slave capacity covers most line-level networks. For a plant mid-migration, this module is a bridge, not a dead end.

Installation and Service Notes

Mount the module per the M340 platform guidelines. Keep the 24V DC external supply clean; the unit draws 300 mA. Label the RJ45 and SUB-D9 cables clearly. Mixed Ethernet and Modbus Plus wiring in one cabinet invites misplugging. During commissioning, verify that each slave responds through the gateway before you cut over production. Keep spare SUB-D9 connectors on hand, since legacy cabling is often the first failure point.

Reliability and Maintenance

This is a solid-state communication module with no moving parts. Inspect the cabinet environment periodically for dust and heat buildup. Check that the 24V DC supply stays within tolerance. Confirm that status indicators on the RJ45 ports show normal link activity. If a segment drops, test the Modbus Plus cabling before suspecting the module. Because the lifecycle status is Active, long-term spares planning is straightforward. Please verify current lifecycle status and availability with SpareTechPLC before ordering.

Compatibility and Integration

The gateway speaks Ethernet Modbus TCP on one side and Modbus Plus on the other. It fits the Modicon M340 platform and supports SNMP for network management. FDR simplifies firmware and configuration file handling. Global Data and Peer cop dialogue support deterministic data exchange where your architecture uses them. Plan your IP addressing and Modbus Plus node addresses before installation.

What to Confirm Before You Buy

Check your existing network for Modbus Plus node count. Confirm you have 24V DC available at 300 mA. Verify that your controller or SCADA master uses Modbus TCP. Decide whether you need both RJ45 ports active or just one. SpareTechPLC stocks industrial automation parts and can help confirm this module fits your M340 setup. Ask about the current ConneXium range status when you request a quote.

Troubleshooting Basics

If slaves do not appear, verify Modbus Plus cabling and termination first. If Ethernet communication fails, check IP settings and switch port status. If the module draws no current, confirm the 24V DC supply. If only some slaves respond, review node addressing and the 128-slave limit. Log intermittent faults; they often point to cabling rather than the gateway.

Figure 1: Front view of the Schneider TCSEGDB23F24FA industrial automation component showing its physical design and enclosure.
Figure 2: Technical layout and connection details for the Schneider TCSEGDB23F24FA industrial automation component.

Specifications

Model / No. TCSEGDB23F24FA
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $253.00