Schneider

STBACI1230 | Schneider 2-Channel Analog Input Module

  • Model STBACI1230
  • Condition In Stock
4.6/5 (16 reviews)
$284.00 Indicative price · request a quote for availability

Discontinued Schneider STBACI1230 Advantys STB 2-channel analog current input module. Verify availability and Modicon X80 replacement options with SpareTechPLC.

Product Description

Why Engineers Still Specify the STBACI1230

When a plant standardizes on the Advantys STB distributed I/O platform, replacing a single analog slice often means matching the exact electrical behavior of the original design. The STBACI1230 from Schneider Electric is a standard 2-channel analog current input module built for that purpose. It accepts 0-20 mA signals and remains compatible with 4-20 mA field devices, giving you a clean path for legacy loop migration.

This module is discontinued and superseded by the Modicon X80 range. That status matters for your upgrade plan, but it does not erase the installed base. Many lines still run Advantys STB islands every day.

Figure 1: Front view of the Schneider STBACI1230 industrial automation component showing its physical design and enclosure.

Technical Specifications That Drive Real Decisions

The STBACI1230 delivers 12-bit resolution across two single-ended channels. In practical terms, that resolution supports stable measurement of pressure, flow, and level transmitters without excessive quantization noise.

Accuracy is specified at ±0.5% FS at 25 °C, with integral linearity of ±0.1% FS typical. Temperature drift sits at ±0.01% FS/°C, so cabinet temperature swings cause only minor measurement shift. A single low-pass filter at 25 Hz nominal suppresses electrical noise on long field runs.

Response time reaches 5 ms for both channels, and the update time is 10 ms for two channels. For most process monitoring loops, that speed is more than adequate. Isolation is a strong point: 1500V AC field-to-bus and 30V DC channel-to-channel. The module also supports hot swapping, which reduces downtime during maintenance.

Key Parameters at a Glance

Specification Value
Module type Standard analog input module
Channels 2 single-ended
Signal type 0-20 mA current (compatible with 4-20 mA)
Resolution 12 bits
Accuracy ±0.5% FS @25 °C
Isolation 1500V AC field-to-bus, 30V DC channel-to-channel
Supply voltage 24V DC (via PDM)
Protection rating IP20

Where This Module Earns Its Keep

Water treatment plants often use 4-20 mA transmitters for level and dosing control. The STBACI1230 fits those loops directly. Its 100 mA per channel field supply with electronic short-circuit protection simplifies wiring to two-wire transmitters.

In food and beverage processing, analog inputs monitor temperature and pressure skids. The IP20 rating suits clean control cabinets, and hot swapping lets technicians replace a slice without shutting down the entire island.

For legacy system owners, the discontinued status creates a sourcing challenge. SpareTechPLC helps engineers locate remaining stock and plan a migration to Modicon X80 when the time comes.

Figure 2: Technical layout and connection details for the Schneider STBACI1230 industrial automation component.

Installation and Setup Guidance

The STBACI1230 mounts on an STBXBA1000 I/O base with a 13.9 mm width. Power comes through the STBPDT3100 PDM at 24V DC, and the module draws 100 mA at 5V DC from the bus. Verify that your PDM and base match these part numbers before installation.

Because the module is hot swappable, you can replace it under power in supported configurations. Always follow your site’s lockout procedures and the manufacturer’s safety manual. Never exceed the maximum input of 25 mA or 50V DC, even briefly.

Maintenance and Long-Term Reliability

Inspect terminal connections periodically for corrosion or loosening. The 25 Hz input filter handles normal industrial noise, but severe electrical interference may require reviewing cable routing and shielding. The IP20 rating means the module belongs inside a protected enclosure.

Given the discontinued lifecycle, treat every spare as a strategic asset. Keep at least one verified spare on the shelf if the line runs continuously. When replacement becomes necessary, contact SpareTechPLC to confirm availability and discuss Modicon X80 alternatives.

Compatibility and Integration Notes

The STBACI1230 operates within the Advantys STB distributed I/O system. It communicates through the island bus and requires the STBPDT3100 PDM for 24V DC supply. The STBXBA1000 base provides the physical and electrical interface. Confirm these supporting components remain available before committing to a like-for-like replacement.

What to Verify Before You Buy

Ask three questions. First, does your application require 0-20 mA or 4-20 mA? The module supports both. Second, do you have the correct PDM and base? Third, what is your migration timeline to Modicon X80? SpareTechPLC can help you answer all three and source the right parts.

Please verify current lifecycle status and availability with SpareTechPLC before ordering.

Specifications

Model / No. STBACI1230
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $284.00

Additional Information

Discontinued Schneider STBACI1230 Advantys STB 2-channel analog current input module. 0-20 mA, 12-bit, 1500V AC isolation. Verify availability and Modicon X80 replacement options with SpareTechPLC.

Shipping & Returns

Shipping Port
Xiamen

Downloads

Download Instruction Manual (STBACI1230.pdf)

Latest News