TSXPBY100 | Schneider Profibus-DP Module for Premium PLCs

Contact for Price Fast reply within 24 hours

Schneider TSXPBY100 Profibus-DP option module for Modicon Premium PLCs. Supports 9.6 Kbit/s to 12 Mbit/s, up to 124 slaves, 4096 I/O. Order today.

Product Description

Introduction

In the 1980s, factory floors relied on proprietary networks that locked engineers into single-vendor ecosystems. The shift to open fieldbus standards changed everything. Schneider Electric embraced this evolution with the TSX Micro PLCs product line, delivering flexible communication options for industrial automation. The TSXPBY100 Profibus-DP option module represents that commitment, bridging Modicon Premium PLCs with one of the world’s most widely deployed industrial networks. This module lets you integrate legacy control systems into modern Profibus architectures without replacing your existing PLC infrastructure.

Figure 1: Front view of the Schneider TSXPBY100 industrial automation component showing its physical design and enclosure.

Why the TSXPBY100 Matters for Your Control System

The TSXPBY100 is a Profibus-DP V0 module kit designed for Schneider Electric’s Modicon Premium PLCs. It provides a physical RS485 interface using twisted shielded pairs cable and supports NRZ transmission mode. With a transmission rate spanning 9.6 Kbit/s to 12 Mbit/s, this module adapts to both long-distance and high-speed network segments. At 9.6 Kbit/s, you can achieve a segment length up to 1200 meters without a repeater. At 12 Mbit/s, the module supports 100 meters without a repeater or 400 meters with three repeaters. This flexibility makes it suitable for sprawling production lines and compact machine cells alike.

Key Technical Specifications

Specification Value
Manufacturer Schneider Electric
Product Line TSX Micro PLCs
Module Type Profibus-DP Option Module
Compatibility Modicon Premium PLCs
Transmission Rate 9.6 Kbit/s to 12 Mbit/s
Maximum Segment Length Up to 1200 m at 9.6 Kbit/s
Number of Slaves Up to 124 with repeaters
Input/Output Data Size 4096 inputs / 4096 outputs
Power Supply 5 V DC from rack power supply
Current Consumption 400 mA on 5 V DC
Operating Temperature 0 °C to +60 °C
Storage Temperature -25 °C to +70 °C
Humidity 30% to 95% (non-condensing)
Altitude 0 to 2000 meters
Weight 0.75 lbs (0.34 kg)

Figure 2: Technical layout and connection details for the Schneider TSXPBY100 industrial automation component.

Performance You Can Rely On

The TSXPBY100 handles up to 4096 inputs and 4096 outputs, giving you comprehensive control over distributed I/O across your Profibus network. It supports up to 124 slaves when repeaters extend the bus. The module operates as both a class 1 and class 2 master. Class 1 functions include reading and writing DP slave I/O data, setting slave parameters on power up, checking slave configuration, and transferring diagnostic data. Class 2 master services cover global control and master diagnostic requests. Note that Profibus FMS message handling is not supported. This module draws 400 mA at 5 V DC from the rack power supply, so verify your rack has adequate capacity before installation.

Built for Demanding Industrial Environments

Schneider Electric engineered the TSXPBY100 to withstand harsh conditions. It complies with IEC 68-2-6 for vibration immunity, IEC 68-2-27 for shock immunity, and IEC 1000-4-2 for electrostatic discharge immunity. The operating temperature range of 0 °C to +60 °C suits most climate-controlled industrial settings. Storage tolerance extends from -25 °C to +70 °C. Humidity can range from 30% to 95% non-condensing, and the module operates at altitudes up to 2000 meters. These ratings ensure reliable performance in factories, processing plants, and remote installations.

Installation and Setup

The TSXPBY100 kit includes a host module for the PCMCIA card, a T-junction box for tapping the main bus, and a Profibus DP PCMCIA card with an integrated 0.6 m connecting cable. Install the host module in your Modicon Premium PLC rack, then insert the PCMCIA card. Use the T-junction box to connect to the Profibus network via twisted shielded pairs cable. Ensure the rack power supply provides 5 V DC at sufficient current. Verify that your network termination and grounding follow Profibus standards. Before powering up, confirm all connections are secure and the module is properly seated.

Compatibility and Integration

The TSXPBY100 works with Modicon Premium PLCs and Atrium slot-PLCs. It communicates over Profibus-DP using RS485 physical interface. The module supports master class 1 and master class 2 access methods. It handles check slave configuration on power up, manage monitoring requests, read/write DP slave I/O data, set slave parameters, and transfer slave diagnostic data. No master/master dialogue is supported for class 2 master. Profibus FMS message handling is not supported. This module integrates seamlessly into existing Profibus networks, allowing you to add Schneider control to mixed-vendor environments.

Selection Guide

Before purchasing the TSXPBY100, verify your PLC model supports this option module. Check that your rack power supply can deliver 400 mA at 5 V DC. Confirm your network speed and distance requirements match the module’s capabilities. If you need to cover long distances, plan for repeaters to extend segment length and slave count. The kit includes the host module, T-junction box, and PCMCIA card with cable. For availability and replacement options, contact SpareTechPLC. Please verify current lifecycle status and availability with SpareTechPLC before ordering.

Frequently Asked Questions

Q: What is the maximum number of slaves the TSXPBY100 can support?

A: It supports up to 124 slaves when repeaters are used to enhance connectivity.

Q: Can I use the TSXPBY100 with a non-Schneider PLC?

A: The module is designed for Modicon Premium PLCs and Atrium slot-PLCs. Compatibility with other PLC brands is not specified.

Q: What is the power consumption of this module?

A: It draws 400 mA at 5 V DC from the rack power supply.

Q: Does the TSXPBY100 support Profibus FMS?

A: No, Profibus FMS message handling is not supported.

Q: What is included in the TSXPBY100 kit?

A: The kit includes a host module for the PCMCIA card, a T-junction box for bus tapping, and a Profibus DP PCMCIA card with an integrated 0.6 m connecting cable.