TSXMRPC007M | Schneider 512 KB Flash Memory Module for TSX Micro PLCs

Contact for Price Fast reply within 24 hours

Schneider TSXMRPC007M: 512 KB flash memory module for TSX Micro PLCs. DIN rail mount, 10-year data retention, 100,000 write cycles. Order now at SpareTechPLC.

Product Description

TSXMRPC007M: A Maintenance Engineer’s Guide to Reliable PLC Memory Expansion

When a TSX Micro PLC runs out of program space, production stops. The Schneider Electric TSXMRPC007M solves this by adding 512 KB of flash memory to your existing controller. This compact module keeps your automation running without a full system overhaul. It stores data for up to 10 years and handles 100,000 write cycles. For maintenance teams, that means fewer replacements and less downtime.

Why This Module Belongs in Your Spare Parts Cabinet

Downtime kills productivity. A failed memory module can halt an entire production line. The TSXMRPC007M is built for tough industrial environments. It operates from 0°C to 60°C and survives shocks up to 15 g. Vibration resistance covers 1.5 mm peak-to-peak from 3 Hz to 13 Hz. These ratings mean the module keeps working even when nearby machinery shakes or temperature swings occur. With DIN rail mounting, you can swap it out in minutes. No special tools required.

Technical Specifications That Matter

Beyond capacity, the TSXMRPC007M delivers practical reliability. Power consumption is just 0.5 W, so it adds almost no load to your control panel. The module weighs only 0.1 kg and measures 35 mm x 90 mm x 60 mm. It fits tight enclosures easily. Data retention lasts 10 years without power. Write endurance reaches 100,000 cycles. That supports frequent recipe changes or data logging. Certifications include CE, UL, and CSA. These confirm the module meets major safety and quality standards.

Specification Value
Memory Capacity 512 KB
Memory Type Flash memory
Compatibility Schneider Electric TSX Micro PLCs
Operating Temperature 0°C to 60°C
Storage Temperature -25°C to 70°C
Humidity 5% to 95% non-condensing
Shock Resistance 15 g for 11 ms
Vibration Resistance 1.5 mm peak-to-peak from 3 Hz to 13 Hz
Mounting Type DIN rail mounting
Power Consumption 0.5 W
Data Retention 10 years
Write Endurance 100,000 write cycles
Certifications CE, UL, CSA
Weight 0.1 kg
Dimensions 35 mm x 90 mm x 60 mm

Installation and Setup for Service Teams

Installing the TSXMRPC007M takes minutes. First, power down the PLC and lock out the panel. Next, snap the module onto a standard DIN rail inside the enclosure. Connect it to the TSX Micro PLC backplane according to Schneider’s wiring diagrams. Verify that the module sits securely and that no debris blocks ventilation. After power-up, check that the PLC recognizes the added memory. Keep the area clean and dry. Humidity must stay between 5% and 95% non-condensing. Avoid mounting near heat sources that exceed 60°C.

Maintenance and Reliability: Protecting Your Investment

From a maintenance perspective, the TSXMRPC007M requires almost no routine service. Inspect the module every six months for loose connections or dust buildup. Use a dry, lint-free cloth to wipe the exterior. Never open the housing or attempt internal repairs. The flash memory retains data for 10 years, so battery backups become less critical. Write endurance of 100,000 cycles means you can update recipes or logs frequently without wearing out the module. If your facility experiences heavy vibration, check the DIN rail clip quarterly. A secure mount prevents intermittent faults.

Compatibility and Integration with Schneider Systems

The TSXMRPC007M works exclusively with Schneider Electric TSX Micro PLCs. It does not fit Modicon Premium or other platforms. Before ordering, confirm your PLC model matches the TSX Micro family. This module uses flash memory, not SRAM. That distinction matters because flash retains data without power. If your application requires SRAM, look for a different part number. The TSXMRPC007M integrates directly into existing racks. No firmware updates or special configuration tools are needed. Simply install it and let the PLC detect the added capacity.

Selection Guide: What to Verify Before You Buy

Purchasing the wrong memory module wastes time and money. Check three things first. One, confirm your PLC is a TSX Micro model. Two, verify you need flash memory, not SRAM or EEPROM. Three, ensure your control panel has a free DIN rail slot. The TSXMRPC007M comes with CE, UL, and CSA certifications. These may satisfy your site’s compliance requirements. For a reliable supplier, visit SpareTechPLC. They stock this module and can help you confirm compatibility. Always request the part number TSXMRPC007M to avoid substitutions.

Troubleshooting Common Memory Module Issues

If the PLC does not recognize the module, check the DIN rail seating first. A loose connection causes most faults. Next, verify that the PLC firmware supports memory expansion. Some older TSX Micro units may need a firmware update. If data corruption occurs, inspect for excessive vibration or temperature spikes. The module tolerates 15 g shock and 1.5 mm vibration, but extreme conditions can still damage it. Finally, confirm that humidity stays within 5% to 95% non-condensing. Condensation leads to shorts and permanent failure. When in doubt, replace the module rather than risk production downtime.

Figure 1: Front view of the Schneider TSXMRPC007M industrial automation component showing its physical design and enclosure.

Latest News

View All News