Schneider

TM2AMI2HT | Schneider Modicon M238 Analog Input Module

  • Model TM2AMI2HT
  • Condition In Stock
4.6/5 (16 reviews)
$226.00 Indicative price · request a quote for availability

Upgrade your Modicon M238 PLC with the Schneider TM2AMI2HT analog input module. 2 high-level channels, 12-bit resolution, and reliable performance.

Product Description

The Challenge of Precise Analog Monitoring

Industrial processes demand precise monitoring of analog signals. When you need to measure current or voltage from sensors, transmitters, or other field devices, a reliable analog input module is crucial. The Schneider TM2AMI2HT is engineered to meet this challenge. It provides two high-level analog inputs for your Modicon M238 logic controller, ensuring accurate data acquisition for your critical applications. This module is designed for seamless integration and dependable operation.

Figure 1: Front view of the Schneider TM2AMI2HT industrial automation component showing its physical design and enclosure.

What Is the Schneider TM2AMI2HT?

The TM2AMI2HT is an I/O expansion module from Schneider Electric, specifically designed for the Modicon M238 logic controller family. It adds two analog input channels to your system, supporting both current and voltage signals. The module accepts 4…20 mA current loops and 0…10 V voltage signals, both non-differential. This flexibility makes it suitable for a wide range of industrial sensors and transmitters. With a 12-bit resolution, the TM2AMI2HT delivers precise digital representation of your analog signals. Its compact design and removable terminal block simplify installation and maintenance.

Key Technical Specifications

The TM2AMI2HT offers robust performance for demanding applications. Here are the critical specifications:

  • Input Channels: 2 analog inputs, high level
  • Input Types: Current 4…20 mA (non-differential), Voltage 0…10 V (non-differential)
  • Resolution: 12 bits
  • LSB Value: 2.5 mV (voltage), 4.8 µA (current)
  • Input Impedance: ≥ 1 MOhm (voltage), 10 Ohm (current)
  • Permissible Continuous Overload: 40 mA (current), 13 V (voltage)
  • Sampling Duration: 10 ms per channel
  • Measurement Error: ±0.2% of full scale at 25 °C
  • Temperature Coefficient: ±0.006% FS/°C
  • Repeat Accuracy: ±0.5% FS
  • Non-Linearity: ±0.2% FS
  • Total Error: ±1% FS
  • Supply Voltage: 24 V DC (20.4…28.8 V)
  • Current Consumption: 50 mA at 5 V DC internal, 40 mA at 24 V DC external
  • Isolation: Photocoupler between channel and internal logic
  • Dielectric Strength: 500 V between I/O and external supply, 500 V between I/O and internal logic
  • Dimensions: 23.5 mm width, 70 mm depth, 90 mm height
  • Weight: 0.085 kg

These specifications ensure accurate and stable signal acquisition, even in environments with temperature variations.

Figure 2: Technical layout and connection details for the Schneider TM2AMI2HT industrial automation component.

Real-World Applications

The TM2AMI2HT is ideal for applications that require precise analog monitoring. Consider these scenarios:

  • Process Control: Monitor temperature, pressure, or flow transmitters that output 4…20 mA signals. The module’s accuracy and repeatability ensure reliable process control.
  • Machine Automation: Read analog sensors in packaging, material handling, or assembly machines. The 0…10 V input can interface with many industrial sensors.
  • Building Management: Use the module to monitor HVAC parameters like temperature or humidity sensors, enabling efficient energy management.

In each case, the TM2AMI2HT provides the critical link between your sensors and your control system.

Installation and Setup Guidance

Proper installation is key to maximizing the performance of your TM2AMI2HT. Follow these guidelines:

  1. Mounting: The module is designed for DIN rail mounting within a Modicon M238 system. Ensure adequate clearance for ventilation and wiring.
  2. Wiring: Use shielded cable for analog signals to minimize electromagnetic interference. Connect the shield at one end only, typically at the sensor or the module.
  3. Terminal Block: The module features a removable screw terminal block for easy wiring. Ensure all connections are secure and correctly polarized.
  4. Supply Voltage: Provide a stable 24 V DC external supply within the specified limits (20.4…28.8 V). Use a properly rated power supply to avoid fluctuations.
  5. Configuration: Configure the module using the programming software for your Modicon M238 controller. Set the input type (current or voltage) and scaling parameters as needed.

Always refer to the product manual for detailed wiring diagrams and configuration instructions.

Maintenance and Reliability

The TM2AMI2HT is designed for long-term reliability. To ensure consistent performance, follow these maintenance tips:

  • Periodic Inspection: Check all wiring connections for tightness and signs of corrosion. Loose connections can cause intermittent signals.
  • Environmental Considerations: Operate the module within its specified temperature range. Avoid exposure to excessive moisture, dust, or vibration.
  • Cleaning: Keep the module surface clean and free of debris. Use a dry, lint-free cloth to wipe the exterior. Do not use solvents or cleaners.
  • Calibration: While the module offers excellent accuracy, periodic calibration of your entire measurement chain (sensor, wiring, and module) is recommended to maintain system accuracy.

By following these practices, you can extend the life of your module and prevent unexpected downtime.

Compatibility and Integration

The TM2AMI2HT is part of the Modicon M238 logic controller family. It is compatible with the following:

  • Modicon M238 Logic Controller: The module expands the I/O capacity of your M238 controller.
  • Twido and Advantys OTB: The module is also range-compatible with these products, offering flexibility in system design.

This compatibility ensures seamless integration into your existing automation architecture.

Troubleshooting Common Issues

If you encounter problems with your analog input module, consider these common issues:

  • No Signal: Check the wiring connections and ensure the sensor is powered. Verify that the input type (current or voltage) is correctly configured.
  • Inaccurate Readings: Check for ground loops or electromagnetic interference. Use shielded cable and ensure proper grounding. Also, verify that the sensor is calibrated.
  • Module Not Recognized: Ensure the module is properly seated in the expansion bus and that the controller firmware supports the module.

If issues persist, consult the product documentation or contact technical support.

Why Choose SpareTechPLC?

SpareTechPLC is your trusted source for industrial automation parts. We offer genuine Schneider Electric products, competitive pricing, and fast shipping. Our knowledgeable team can help you select the right components for your application. When you need reliable automation parts, choose SpareTechPLC.

Please verify current lifecycle status and availability with SpareTechPLC before ordering.

Frequently Asked Questions

What is the resolution of the TM2AMI2HT analog input module?

The TM2AMI2HT provides a 12-bit resolution, allowing for precise digital representation of analog signals. This ensures high accuracy in your measurements.

Can the TM2AMI2HT accept both current and voltage signals?

Yes, the TM2AMI2HT supports both 4…20 mA current and 0…10 V voltage inputs. However, each channel must be configured for the appropriate signal type.

What is the input impedance of the TM2AMI2HT?

The input impedance is ≥1 MOhm for voltage inputs and 10 Ohm for current inputs. This ensures minimal loading on the sensor.

What is the sampling duration of the TM2AMI2HT?

The sampling duration is 10 ms per channel. This allows for fast and responsive data acquisition.

Is the TM2AMI2HT compatible with Twido controllers?

Yes, the TM2AMI2HT is range-compatible with Twido and Advantys OTB, in addition to the Modicon M238 logic controller.

Specifications

Model / No. TM2AMI2HT
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $226.00

Additional Information

Schneider TM2AMI2HT - Analog input module, Modicon M238 logic controller, 2 inputs voltage/current high level, non differential.

Main
Range of product
Modicon M238 logic controller
Product or component type
I/O expansion module
Analogue input number
2
Input level
High level
Analogue input type
current 4...20 mA non differential
voltage 0...10 V non differential
Cross talk
= 1 MOhm voltage
10 Ohm current
Sampling duration
10 ms
Acquisition period
10 ms per channel + 1 controller cycle time
Measurement error
+/- 0.2 % of full scale at 25 °C
Temperature coefficient
+/-0.006 %FS/°C
Repeat accuracy
+/-0.5 %FS
Non-linearity
+/- 0.2 %FS
Total error
+/-1 %FS
Type of cable
Shielded cable
Insulation between channel and internal logic
Photocoupler
Supply
External supply
[Us] rated supply voltage
24 V DC
Supply voltage limits
20.4…28.8 V
Electrical connection
1 removable screw terminal block
Current consumption
50 mA at 5 V DC internal
40 mA at 24 V DC external
Product weight
0.085 kg
Environment
Dielectric strength
500 V between the I/O and the external supply circuit
500 V between the I/O and internal logic
Width
23.5 mm
Depth
70 mm
Height
90 mm
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.5 cm
Package 1 Width
10.5 cm
Package 1 Length
13.0 cm
Package 1 Weight
197.0 g

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Schneider_E696BDE88090E5BEB7_TM2AMI2HT_Service_Manual.pdf)

Latest News

View All News