Schneider

TSXASY800 | Schneider 8-Channel Analog Output Module

  • Model TSXASY800
  • Condition In Stock
4.6/5 (16 reviews)
$286.00 Indicative price · request a quote for availability

Schneider TSXASY800 8-channel analog output module for TSX Micro PLCs. Supports 0-10 V and 0-20 mA outputs with 12-bit resolution.

Product Description

TSXASY800 | Schneider 8-Channel Analog Output Module

When your control system demands precise analog output but space is tight, the Schneider Electric TSXASY800 delivers. This compact analog output module, part of the TSX Micro PLC family, provides eight independent channels that handle both voltage and current signals. With a 12-bit resolution and accuracy of ±0.1% of full scale, it ensures your process variables are reproduced faithfully, reducing waste and improving product quality.

Why Choose the TSXASY800?

Many older analog modules suffer from signal drift, slow response, or limited channel counts. The TSXASY800 overcomes these issues with a fast 1 ms response time per channel and robust isolation of 500 V between channels and ground. This means you get reliable, repeatable output even in electrically noisy industrial environments. Whether you are upgrading an existing TSX Micro system or building a new control panel, this module offers a straightforward path to accurate analog control.

Technical Specifications Breakdown

Here are the key parameters that define the TSXASY800’s performance:

| Parameter | Value |

|———–|——-|

| Analog Output Channels | 8 |

| Output Types | Voltage or current |

| Voltage Output Range | 0 to 10 V |

| Current Output Range | 0 to 20 mA |

| Resolution | 12-bit |

| Accuracy | ±0.1% of full scale |

| Response Time | 1 ms per channel |

| Power Supply | 24 V DC |

| Power Consumption | 5 W |

| Operating Temperature | 0 to 60 °C |

| Storage Temperature | -40 to 85 °C |

| Humidity (Operation) | 5 to 95% non-condensing |

| Isolation (Channel to Ground) | 500 V |

| Load Impedance (Current Output) | Minimum 500 ohms |

These specifications show a module built for precision and durability. The wide operating temperature range and high humidity tolerance make it suitable for harsh production floors.

Real-World Applications

Process Control Upgrades

If you are modernizing a legacy TSX Micro PLC setup, the TSXASY800 is a drop-in replacement for older analog output cards. Its 8 channels let you control multiple valves, drives, or recorders from a single module, saving panel space and reducing wiring complexity. The 0-10 V output is ideal for variable frequency drives, while 0-20 mA works well with transducers and actuators.

Precision Dosing and Mixing

In chemical or pharmaceutical batch processes, accurate analog signals are critical. The ±0.1% accuracy and 12-bit resolution ensure that your pumps and feeders receive the exact command values, minimizing batch-to-batch variation. The fast 1 ms response helps maintain tight loop timing.

Installation and Setup Guidance

Installing the TSXASY800 is straightforward. It connects via a single SUB-D 25 connector, which simplifies wiring and reduces the chance of loose connections. Before mounting, verify that your TSX Micro rack has an available slot and that the module’s power supply meets the 24 V DC requirement. Always observe proper ESD precautions when handling the module. For current outputs, ensure the load impedance is at least 500 ohms; for voltage outputs, a load greater than 1000 ohms is recommended. Double-check your wiring against the terminal descriptions provided in the manual to avoid short circuits.

Maintenance and Reliability

The TSXASY800 is designed for long service life with minimal upkeep. Its short-circuit and overload protection help prevent damage from wiring faults. To maintain reliability, periodically inspect the module for dust accumulation and ensure adequate airflow around the PLC rack. The module’s operating temperature range of 0 to 60 °C means it can handle most industrial enclosures, but avoid placing it near heat sources. Because there are no moving parts, routine maintenance is limited to visual checks and verifying that all connections remain tight.

Compatibility and Integration

The TSXASY800 is engineered for the Schneider Electric TSX Micro PLC family. It integrates seamlessly with the TSX Micro rack and is programmed using standard PLC software. The module supports both current and voltage outputs, giving you flexibility in connecting to various field devices. Before ordering, confirm that your PLC model and firmware are compatible with this module. SpareTechPLC can assist with compatibility checks.

Selection Guide and Purchasing Advice

When selecting the TSXASY800, consider your specific output needs. Do you need voltage or current signals? How many channels? The TSXASY800 covers both with 8 channels, making it a versatile choice. Verify your power supply: the module draws 200 mA at 5 V DC and 300 mA at 24 V DC. Also, check the environmental conditions of your installation site to ensure they fall within the specified ranges. SpareTechPLC offers genuine Schneider modules with fast shipping, so you can get your system running without delay.

Troubleshooting and Common Issues

If you encounter problems with the TSXASY800, start with these steps:

  1. No output signal: Check that the module is properly seated in the rack and that the 24 V DC supply is present.
  2. Incorrect output value: Verify the load impedance. For current outputs, the load must be less than 600 ohms; for voltage outputs, it must be greater than 1000 ohms.
  3. Communication errors: Ensure the module is recognized by the PLC and that the configuration matches your wiring.

If issues persist, consult the Schneider Electric documentation or contact SpareTechPLC for technical support.

Frequently Asked Questions

Q1: Can the TSXASY800 output both voltage and current simultaneously on different channels?

Yes. Each of the 8 channels can be independently configured for either voltage (0-10 V) or current (0-20 mA).

Q2: What is the minimum load resistance for current output?

For current output, the minimum load impedance is 500 ohms. For voltage output, the load should be greater than 1000 ohms.

Q3: Is the TSXASY800 compatible with all TSX Micro PLCs?

It is designed for the TSX Micro family. Check your specific PLC model’s compatibility before ordering.

Q4: Does the TSXASY800 provide isolation between channels?

It provides 500 V isolation between channels and ground, but channels share a common point.

Q5: What is the response time of the TSXASY800?

The response time is 1 ms per channel, ensuring timely updates for your control loops.

Ready to Upgrade?

Don’t let outdated analog output modules limit your process performance. The Schneider TSXASY800 offers the precision, speed, and reliability you need. Contact SpareTechPLC today to check availability and get a quote. Our team is ready to help you find the right solution for your automation needs.

Figure 1: Front view of the Schneider TSXASY800 industrial automation component showing its physical design and enclosure.
Figure 2: Technical layout and connection details for the Schneider TSXASY800 industrial automation component.

Specifications

Model / No. TSXASY800
Brand Schneider
Condition In Stock
Origin US
Warranty 12 Month
Price $286.00

Additional Information

The Schneider Electric TSXASY800 is part of the TSX Micro PLC series, featuring eight analog output channels. This module supports current and voltage outputs, with specific ranges of 0 to 10 volts and 0 to 20 milliamps.

Technical specifications for TSXASY800
Manufacturer Schneider Electric
Product Line TSX Micro PLCs
Part Number TSXASY800
EAN 3389110876369
Weight 1.00 lbs (0.45 kg)
Number of Channels 8 analog output channels
Output Type Voltage or current
Voltage Output Range 0 to 10 V
Current Output Range 0 to 20 mA
Resolution 12-bit
Accuracy ±0.1% of full scale
Load Impedance Minimum 500 ohms for current output
Humidity 5 to 95% non-condensing
Storage Temperature -40 to 85°C
Operating Temperature 0 to 60°C
Power Consumption 5 W
Power Supply 24 V DC
Isolation 500 V between channels and ground
Response Time 1 ms per channel
Range of Product
Modicon Premium Automation platform
Product or Component Type
Analog output module
Analogue output number
8
Analogue output type
Current 0...20 mA
Current 4...20 mA
Voltage +/- 10 V
Analog/digital conversion
13 bits + sign +/- 10 V
13 bits 0...20 mA
13 bits 4...20 mA
Complementary
Conversion time
5 ms
Measurement resolution
1.28 mV +/- 10 V
2.56 µA 0...20 mA
2.56 µA 4...20 mA
Electrical Connection
1 SUB-D 25 connector
Measurement error
0.14 % of full scale +/- 10 V 25 °C
0.21 % of full scale 0...20 mA 25 °C
0.21 % of full scale 4...20 mA 25 °C
0.28 % of full scale +/- 10 V 0...60 °C
0.52 % of full scale 0...20 mA 0...60 °C
0.52 % of full scale 4...20 mA 0...60 °C
Isolation between channels
Common point
Isolation between channels and bus
1000 Vrms
Isolation between channels and ground
1000 Vrms
Protection Type
Short-circuit protection
Overload protection
Output voltage limits
<= 30 V Load impedance ohmic < 600 Ohm 0...20 mA 1000 Ohm +/- 10 V
Maximum load inductance
300 µH
Maximum load capacitance
0.1 µF
Marking
CE
Current consumption
200 mA 5 V DC
300 mA 24 V DC
Module format
Standard
Terminals description PLC n°1
(16)OUT_ANA_CUR#1
(13)IN_ANA_STD#
(24)OUT_ANA_VOLT#7
(8)OUT_ANA_CUR#4
(20)OUT_ANA_COM#4
(1)OUT_ANA_VOLT#0
(17)OUT_ANA_COM#2
(4)OUT_ANA_VOLT#2
(9)OUT_ANA_COM#5
(11)OUT_ANA_CUR#6
(19)OUT_ANA_CUR#3
PW_NEG#
(25)OUT_ANA_CUR#7
(3)OUT_ANA_COM#1
(12)OUT_ANA_COM#7
(5)OUT_ANA_CUR#2
(6)OUT_ANA_COM#3
(15)OUT_ANA_VOLT#1
(18)OUT_ANA_VOLT#3
(22)OUT_ANA_CUR#5
(10)OUT_ANA_VOLT#6
PW_POS#
(14)OUT_ANA_COM#0
(23)OUT_ANA_COM#6
(2)OUT_ANA_CUR#0
(7)OUT_ANA_VOLT#4
(21)OUT_ANA_VOLT#5
Net Weight
1.01 lb(US) (0.46 kg)
Environment
Standards
93/68/EEC
CSA C22.2 No 213 Class I Division 2 Group A
CSA C22.2 No 142
73/23/EEC
CSA C22.2 No 213 Class I Division 2 Group B
89/336/EEC
CSA C22.2 No 213 Class I Division 2 Group D
UL 508
IEC 61131-2
92/31/EEC
CSA C22.2 No 213 Class I Division 2 Group C
Product Certifications
BV
RINA
DNV
LR
ABS
RMRS
GL
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative Humidity
10…95 % without condensation for operation
5…95 % without condensation for storage
Operating altitude
0...6561.68 ft (0...2000 m)
Protective treatment
TC
IP Degree of Protection
IP20
Pollution degree
2
Ordering and shipping details
Category
22558-TSX PREMIUM, ATRIUM & PL7 PRO
Discount Schedule
PC22
GTIN
3389110876369
Returnability
No
Country of origin
FR
Packing Units
Unit Type of Package 1
PCE
Nbr. of units in pkg.
1
Package 1 Height
2.2 in (5.5 cm)
Package 1 Width
7.09 in (18.0 cm)
Package 1 Length
10.2 in (26.0 cm)
Package weight(Lbs)
16.4 oz (465.0 g)

Description
The TSXASY800, manufactured by Schneider Electric, is a component from the TSX Micro PLCs line designed for intricate process control. This module accommodates eight analog output channels, which can output either voltage or current signals. Its output voltage range extends from 0 to 10 volts, and the range for current output is established from 0 to 20 milliamps.

Resolution for the signals generated by this module is set at a precise 12 bits, ensuring an accurate representation of the desired output variables. Additionally, it boasts an impressive accuracy of ±0.1% of full scale, effectively minimizing deviations from expected performance.

For current outputs, a minimum load impedance of 500 ohms is recommended. This requirement guarantees that the system operates optimally without unwanted signal degradation. The module’s compact dimensions of 125 x 100 x 40 mm make it suitable for space-constrained installations.

When considering environmental tolerances, the TSXASY800 performs within a 5 to 95% humidity range without condensation. In terms of temperature, it operates efficiently between 0 and 60°C and can withstand storage temperatures as low as -40°C and as high as 85°C.

The TSXASY800 requires a 24 V DC supply and consumes 5 watts during operation. For enhanced safety, this module features an isolation rating of 500 volts between channels and ground, reducing the risk of electrical interference.

The response time per channel is quick, clocking in at a mere 1 millisecond, thus ensuring timely output changes in most control applications.

Shipping & Returns

Shipping Port
Xiamen
Shipping Details
Ships within 1-3 business days after payment via DHL / FedEx / UPS Express, or by sea/air freight for bulk orders. Tracking number is provided the same day the parcel leaves our warehouse.
Return Policy
30-day return for unused items in original packaging. All parts are covered by a 12-month warranty against defects; DOA units are replaced free of charge.

Downloads

Download Instruction Manual (Schneider_E696BDE88090E5BEB7_TSXASY800_Service_Manual.pdf)

Latest News

View All News